Home Products Hotowell Products Energy Saver Controller HTW-ES6201 PIR Occupancy Module For Hotel FCU System
Energy Saver Controller HTW-ES6201 PIR Occupancy Module For Hotel FCU System
Energy Saver Controller HTW-ES6201 PIR Occupancy Module For Hotel FCU System Energy Saver Controller HTW-ES6201 PIR Occupancy Module For Hotel FCU System Energy Saver Controller HTW-ES6201 PIR Occupancy Module For Hotel FCU System Energy Saver Controller HTW-ES6201 PIR Occupancy Module For Hotel FCU System Energy Saver Controller HTW-ES6201 PIR Occupancy Module For Hotel FCU System

Energy Saver Controller HTW-ES6201 PIR Occupancy Module For Hotel FCU System

Product ID : HTW-ES6201
Product Tags : Hotel Occupancy System
Product Attributes :

HTW-61-ES6201 is designed to control electrical consumption by detecting occupied/unoccupied presence, in order to connect/disconnect the air conditioning equipment and lighting automatically when the customer accesses or leaves the room.

Product Description

Product Description

Energy Saver Controller HTW-ES6201 PIR Occupancy Module For Hotel FCU System 

>> General


HTW-61-ES6201 is designed to control electrical consumption by detecting occupied/unoccupied presence, in order to connect/disconnect the air conditioning equipment and lighting automatically when the customer accesses or leaves the room.


>> PIR presence detector operating algorithm

HTW-61-ES6201 has 1 input (E1) for a magnetic room contact placed on the doorframes of the room;
1 input (E2) for a magnetic window contact placed on the window frames.
3 inputs(E3,E4,E5) for PIR presence detectors.
When the door of the room is open, the energy saving system is activated instantly, and feed the following three outputs:
S1-Air-conditioning output with anti-humidity mode;
S2-Air-conditioning/Lighting output with delay time;
S3-Lighting output with delay time;
Once the door is closed, the system will try to determine if there is movement within 3s~T4 in the room

 

>> Magnetic window contact operating algorithm

If a magnetic window contact switch is connected to the terminals 12-13, when the contact is open, the output S1 will disconnect after 1min, until closing window contact again.

Energy Saver Controller Htw-Es6201 PIR Occupancy Module for Hotel Fcu System

Energy Saver Controller Htw-Es6201 PIR Occupancy Module for Hotel Fcu System
>> Wiring Diagram
Energy Saver Controller Htw-Es6201 PIR Occupancy Module for Hotel Fcu System

Application

 

Energy Saver Controller Htw-Es6201 PIR Occupancy Module for Hotel Fcu System

Packaging & Shipping

Energy Saver Controller Htw-Es6201 PIR Occupancy Module for Hotel Fcu System

Company Profile

Energy Saver Controller Htw-Es6201 PIR Occupancy Module for Hotel Fcu SystemEnergy Saver Controller Htw-Es6201 PIR Occupancy Module for Hotel Fcu System

FAQ

 

Energy Saver Controller Htw-Es6201 PIR Occupancy Module for Hotel Fcu System

Online Inquiry