Home Products Hotowell Products 2 way 3 way Water Control Motorized Valve Electric Actuator Valve for Fan Coil Unit
2 way 3 way Water Control Motorized Valve Electric Actuator Valve for Fan Coil Unit
2 way 3 way Water Control Motorized Valve Electric Actuator Valve for Fan Coil Unit 2 way 3 way Water Control Motorized Valve Electric Actuator Valve for Fan Coil Unit 2 way 3 way Water Control Motorized Valve Electric Actuator Valve for Fan Coil Unit 2 way 3 way Water Control Motorized Valve Electric Actuator Valve for Fan Coil Unit 2 way 3 way Water Control Motorized Valve Electric Actuator Valve for Fan Coil Unit

2 way 3 way Water Control Motorized Valve Electric Actuator Valve for Fan Coil Unit

Product ID : HTW-W27
Product Tags : Motorized Zone Valve
Product Attributes :

HTW-W27 Series Motorized Valves are used to control the flow of hot water/chilling water, in heating/ cooling or air-conditioning applications so as to control room temperature indirectly. It consists of Actuator and Valve Body. The valve is normally closed. When thermostat(with NTC sensor)transfers a signal to actuator, which switch on power supply, and then opens valve letting hot water or chilling water to fan coil unit. If the room temperature reaches set-point, the thermostat transfers a signal to actuator to cut off the power supply and spring return switches the valve off, and stops the flow of hot or chilling water. Therefore, the room temperature could be kept as a constant temperature through valve opened or closed.

Product Description
2 way 3 way Water Control Motorized Valve Electric Actuator Water Valve for Fan Coil Unit
Product Description

>> General                                       

 

 

HTW-W27 Series Motorized Valves are used to control the flow of hot water/chilling water, in heating/ cooling
or air-conditioning applications so as to control room temperature indirectly. It consists of Actuator and Valve Body.
The valve is normally closed. When thermostat(with NTC sensor)transfers a signal to actuator, which switch on power supply,
and then opens valve letting hot water or chilling water to fan coil unit. If the room temperature reaches set-point,
the thermostat transfers a signal to actuator to cut off the power supply and spring return switches the valve off,
and stops the flow of hot or chilling water. Therefore, the room temperature could be kept as a constant temperature through valve opened or closed.

 

 

>> Specification                         

>>Wiring Diagram                

>> Dimensions                            
Model
A
B
C
W27-215
70
23
86
W27-220
87
23
93
W27-225
94
25
95
W27-315
70
33
86
W27-320
87
27
93
W27-325
94
43
95
Certifications
Factory Show
Online Inquiry