Home Products Motorized Valves Motorized Zone Valve 2/3/4 way NC/NO Electric Thermal Valve thermostatic radiator valve
2/3/4 way NC/NO Electric Thermal Valve thermostatic radiator valve
2/3/4 way NC/NO Electric Thermal Valve thermostatic radiator valve 2/3/4 way NC/NO Electric Thermal Valve thermostatic radiator valve 2/3/4 way NC/NO Electric Thermal Valve thermostatic radiator valve 2/3/4 way NC/NO Electric Thermal Valve thermostatic radiator valve 2/3/4 way NC/NO Electric Thermal Valve thermostatic radiator valve

2/3/4 way NC/NO Electric Thermal Valve thermostatic radiator valve

Product ID : HTW-TV02 series
Product Attributes :

HTW-TV02-VA Thermal Valve Actuator is designed to control the open/close of the pipe of chilled/hot water for HVAC system so as to control the indoor temperature and maintain a thermal room temperature.

It is installed on the chilled/hot water pipe, and the valve is controlled to open or close via the signal send from thermostat. The thermostat sends a signal to open the thermal valve to cool/ heat the room via heat exchange from the cooling/heating media, like chilled/heating water.

2 models for options:

 HTW-TV02-VAC

 HTW-TV02-VAO

HTW-TV02-VAC fits for normally closed valve bodies HTW-TV02-VBC series 

HTW-TV02-VAO fits for normally open valve bodies HTW-TV02-VBO series

Product Description

1513244464213130.png

HTW-TV02 Thermal Valve.pdf

 >> General                                      

HTW-TV02-VA Thermal Valve Actuator is designed to control the open/close of the pipe of chilled/hot water for HVAC system so as to control the indoor temperature and maintain a thermal room temperature.

It is installed on the chilled/hot water pipe, and the valve is controlled to open or close via the signal send from thermostat. The thermostat sends a signal to open the thermal valve to cool/ heat the room via heat exchange from the cooling/heating media, like chilled/heating water.

2 models for options: 

HTW-TV02-VAC 

HTW-TV02-VAO

HTW-TV02-VAC fits for normally closed valve bodies HTW-TV02-VBC series 

HTW-TV02-VAO fits for normally open valve bodies HTW-TV02-VBO series

 >> Specification                            

Housing Material PA6110
Color White
Control Element Electro-thermal Wax Sensor
Working Force Intensity (F) & Direction 80n≤ f<130n; direction: downward
Connector For HTW-TV02-VB1/ VB2 Valves M30x1.5
Working Ambient Temperature    -0.5℃~60℃
First Fully Open 5~6.5 minutes (at 25℃)
Protection Class IP40
Power Consumption 1.1VA
Max. Impact Current 24v 1.2A
110v 0.9A
220v/230v 0.7A
Lead Wire 1M Length (2-Core)
Net Weight 94g

 >> Dimensions                              

Dimension TV02VA.jpg

 >> Valve Body                                 

TV02 Valve body.jpg

HTW-TV02-VB series valve body is designed for temperature control in the HVAC circumstance.

There are three port type models:

--HTW-TV02-VB*-2**2 Way Valve Body

--HTW-TV02-VB-3**3 Way Valve Body

--HTW-TV02-VB-4**4 Way Valve Body

HTW-TV02-VB*-2** 2 Way Valve Body varies from 2 types as below:

--Normally close(N.C.) HTW-TV02-VBC-2**

For the normally close type valve, actuator drives the piston to open the valve on direct way and close it on angle way.

--Normally open(N.O.) HTW-TV02-VBO-2**

For the normally open 2-way valve, actuator drives to close it. Spring is used to return the piston.

These valve bodies feature with condensed structure, reliability and convenient installation.

 >> Specification                           

Materials Valve body Forging brass
Valve stem Stainless steel (1cr18ni9)
Spring Stainless steel wire (1cr18ni9)
Inner cover Pbt
Piston Frpa-66
O-sealing- ring Nitrile rubber
Valve body rating pressure 1.6mpa
Stroke 4.5 (mm)
Max. Allowed flow speed 3m/s
Allowed liquid Water, water + glycol
Temperature 5~95℃
Leakage 0 (tight close-off on direct and angle way)

 >> Model Discription                   

HTW-TV02-VB*- C/O 2002-3-4 2/3/4   port 09 A40
Valve Body Code N.C/N.O. Valve Port Type DN15/DN20 Kvs Code Distance of the Centers
(Only for the 4 Outlet Valve)
Valve Body C=Normally Closed O=Normally Open Only   available in 2-way valve 2—2-way 3—3-way 4—3-way,           4-outlet 15=G1/2    20=G3/4 09—Kv=0.25
    10—Kv=0.40
    11—Kv=0.60
    12—Kv=1.00
    13—Kv=1.60
    20—Kv=2.00
    23—Kv=2.50
   
A35—35mm centers A40—40mm centers A50—50mm centers

 >> Installation                               

Before the installation, please make sure the pipe is clean (no soldering scraps), so the valve piston won’t be blocked, and the flow direction indicated on the valve body is correct. Actuator should be mounted above the valve body. We recommend using 3-way valve as mixing valve.

*2-way valve:

A→AB normally open or normally close

*3-way valve:

A→AB normally close B→AB normally open

Flow direction details please refer as below pictures

installation-TV02.jpg

 >> Hotowell Products                 

hotowell hvac products

 >> FAQ                                           

Online Inquiry